Stair Calculator with Landing

in

Type it the way you read the tape: 68 1/2, 5' 8 1/2", 68.5 or 174cm.

Type your total rise and the answer appears here.

Code check runs as you type
Where to measure
Where to measure total riseTotal risemeasure straight downlevel off the finished deckdeck or floorfinished ground or floor

Measure from the top of the finished upper floor or deck straight down to where the bottom step will land. Not level ground? Measure at the landing spot.

Drag, or use the arrow keys
AdjustTread, riser, lumber, nosing, units — the drawing updates as you go

Steps

Top of stair

Lumber

Stringer stock

Space (optional)

Show results in

Cut sheet

Your marks, cuts and shopping list fill in here.

Code check

  • Runs as soon as you enter a total rise.

Based on the IRC (2021 R311.7 / 2024 R318.7). Local codes vary — confirm with your building department before building.

When a staircase is too tall for a single flight, or when room layout requires a 90-degree turn (L-shaped) or 180-degree turn (U-shaped switchback), an intermediate landing is essential. Under the International Residential Code (IRC), any staircase with a vertical rise exceeding 151 inches (12 feet 7 inches) legally requires a landing platform.

This stair calculator with landing computes your flight split, landing platform height, stringer lengths, and horizontal runs while keeping every riser uniform.


How to Use This Stair Calculator with Landing

  1. Enter your total rise: Measure the vertical distance from finished lower floor to finished upper floor.
  2. Choose your flight split: The calculator divides risers evenly between flights. Under Adjust, set the number of risers before the landing to match doorways, walls, or room geometry.
  3. Review both flights: Check the landing platform height, horizontal run for each flight, stringer lengths, and code badges. Print your cut sheet to build lower stringers, the landing, and upper stringers.

How Stairs with Landings Are Calculated

Building a two-flight staircase requires treating both flights as one continuous climb: every riser in both flights must have the exact same height, within 3/8” total variance.

1. Total Risers and Unit Rise

Determine total risers needed for the overall elevation:

Total Risers = Total Rise ÷ 7.75, rounded up
Unit Riser Height = Total Rise ÷ Total Risers

Because unit rise is locked across the system, both flights share identical step heights.

2. Flight Split and Landing Height

Splitting 14 risers at 7 risers creates a balanced midpoint:

Landing Height = Lower Risers × Unit Riser Height

The landing platform serves as the top tread of the lower flight and the starting floor of the upper flight.

3. Flight Runs and Dimensions

For each flight, tread count is risers minus one:

Lower Flight Run = (Lower Risers - 1) × Tread Depth
Upper Flight Run = (Upper Risers - 1) × Tread Depth

This cuts total straight-line horizontal run in half, allowing stairs to fit compact spaces.

4. IRC Landing Code Requirements (R311.7.6)


Worked Example: 108” Total Rise (9-Foot Ceiling)

A 9-foot ceiling with 108 inches total rise, split evenly with a landing at 7 risers, using a 10 1/2-inch tread depth:

Both flights comply fully with IRC codes.


Residential Stair Code for Landings (IRC R311.7 / R318.7)

Stairs with intermediate landings must meet these standards:

Code Dimension IRC Requirement Practical Construction Note
Max Flight Rise 151 inches (12’ 7”) Flights exceeding 151” must include a landing
Minimum Landing Depth 36 inches Measured along the path of travel
Minimum Landing Width Matches stair width Cannot be narrower than the stairway (min 36”)
Max Riser Height 7 3/4 inches Must be uniform across both flights
Min Tread Depth 10 inches Measured nosing-to-nosing
Max Riser Variation 3/8 inch Greatest vs smallest riser between flights
Min Headroom 6’ 8” (80”) Clearance above tread nosings and landing floor
Handrail Requirement Required at 4+ risers Continuous handrail on each flight

Based on the IRC (2021 R311.7 / 2024 R318.7). Local codes vary — confirm with your building department before building.


Frequently Asked Questions

What is the maximum rise before a stair landing is required?

Under IRC Section R311.7.3, a landing is required on any staircase where the vertical rise between floors or levels exceeds 151 inches (12 feet 7 inches).

What size does a stair landing need to be?

Every landing must measure at least 36 inches in the direction of travel and must be at least as wide as the stairway itself (typically 36 inches or wider).

Can riser heights differ between lower and upper flights?

No. The IRC requires all risers within a staircase—including those before and after a landing—to remain uniform within 3/8 of an inch. Changing riser height between flights causes trip hazards.

What is the difference between an L-shaped and U-shaped stair landing?

An L-shaped stair turns 90 degrees at the landing, requiring a square platform (at least 36”x36”). A U-shaped switchback stair turns 180 degrees, requiring a platform at least double the stair width (typically 36”x72”).

How do I calculate the height of my landing platform?

Multiply the number of risers in your lower flight by your unit riser height. For example, 7 risers of 7 11/16 inches gives a finished landing surface height of exactly 54 inches.

Do I drop the bottom of the upper flight stringer?

Yes. If the upper stringer rests directly on the finished floor or decking of the landing platform, trim the thickness of one tread off the bottom of the upper stringer, just like the lower flight.